Heat pump installation diagrams

How the parts actually connect, for air source and ground source systems. Useful whether you are comparing quotes or just working out what a heat pump would mean for your house.

Air source heat pump installation diagram

An air source system has an outdoor unit containing the refrigerant circuit, connected by flow and return pipes to the wet heating system inside.

Air source heat pump installation diagram showing outdoor unit, evaporator, compressor, condenser and expansion valve, flow and return pipes, hot water cylinder, radiators, underfloor heating and controls

Reading the diagram

Ground source heat pump installation diagram

Ground source replaces the outdoor unit with buried pipework, and the heat pump itself moves indoors.

Ground source heat pump installation diagram comparing horizontal ground loops in trenches with a vertical borehole, both feeding an indoor heat pump and hot water cylinder

Horizontal loops against boreholes

What is not on the diagram

Two things that decide whether an installation works, and which no diagram shows. The first is emitter sizing: radiators must be capable of heating each room at the design flow temperature. The second is the heat loss calculation behind the unit selection. A diagram tells you what connects to what. It cannot tell you whether the system was sized correctly, which is the thing that actually determines whether you are warm and what it costs.

Diagram questions

What does a heat pump installation look like?

Outside, a boxed unit roughly the size of a large washing machine standing on a base or wall brackets, with two insulated pipes running into the building. Inside, a hot water cylinder, a small controls panel and your existing radiators, some of which may be larger than before.

How does a heat pump installation work?

The outdoor unit evaporates a refrigerant using heat from the air or ground. A compressor raises that refrigerant's temperature. A condenser transfers the heat into your central heating water. An expansion valve drops the pressure and the cycle repeats. The heating water then circulates to radiators, underfloor heating and the hot water cylinder.

What is the difference between air source and ground source layouts?

Air source puts the heat exchanger in an outdoor unit that takes heat from the air. Ground source puts it in buried loops or boreholes and the heat pump itself sits indoors, usually in a plant room or utility. Everything downstream of the heat pump, meaning cylinder, radiators and controls, is essentially the same.

Free, no obligation

Talk it through with an engineer

Every quote starts with a proper heat loss survey, not a guess from your floor area. Tell us about the property and we will come back with honest advice, a clear price and the grant position spelled out.

  • Free heat loss survey and system design
  • MCS certified, so grant funding applies
  • We handle the grant paperwork for you
  • Straight answer if a heat pump is the wrong call

Get your free heat pump quote

Tell us about your property and an MCS-certified engineer will be in touch, usually the same working day.

No obligation. We only use your details to respond to your enquiry.

Find out what a heat pump would cost you

Get a free, no-obligation quote for heat pump installation in Tunbridge Wells, with the grant deducted so you see the real figure. We come back to you the same working day.

Get my free quote